Vaccine Cooling
For this lab the goal was to be able to model lump mass cooling in order to accomplish the goal of maintaining a suitable temperature range for our “vaccines.”
Analyzed several different test runs to determine R and C values for our model
Created a MatLab model to accurately predict the temperature vs. time behavior for our setup
For the final test we were given parameters that we input into our model to see if it would correctly output a setup that would keep the vials at the correct temperature over the allotted time range
In the end, my partner and I were able to accurately model the temperature change over time and keep our “vaccines” viable