For this lab the goal was to be able to model lump mass cooling in order to accomplish the goal of maintaining a suitable temperature range for our “vaccines.”

  • Analyzed several different test runs to determine R and C values for our model

  • Created a MatLab model to accurately predict the temperature vs. time behavior for our setup

  • For the final test we were given parameters that we input into our model to see if it would correctly output a setup that would keep the vials at the correct temperature over the allotted time range

  • In the end, my partner and I were able to accurately model the temperature change over time and keep our “vaccines” viable